download PDF

Abstract

It is impossible to imagine blast furnaces work without statuses monitoring systems of feeding equipment in modern conditions. Stationary system of vibration diagnostics of a main gearbox of blast furnace number six bell-less top at OJSC “Magnitogorsky iron & steel works Russia” was implemented by specialists of CJSC «KonsOM SKS». The system monitors the level of vibration diagnostics mean square value (RMS) according to all-Union State Standard 10816, and also the vibration speed RMS on the frequencies, which characterize the defects of gear antifriction bearings.

Keywords

Stationary system of vibration diagnostics, vibration sensor, vibration diagnostics, blast furnace, defect, gear, mean square value.

Panov Alexander Nikolaevich – Ph.D.(Eng.), head of process automation department, CJSC «KonsOM SKS», Magnitogorsk, Russia. E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

Chistjakov Dmitrij Vladimirovich – Ph.D. in Sociology, chief executive officer, CJSC "KonsOM SKS", Magnitogorsk, Russia.

Korobejnikov Stanislav Mihajlovich – chief engineer, CJSC "KonsOM SKS", Magnitogorsk, Russia.

Guzej Ksenija Evgenievna – engineer, CJSC "KonsOM SKS", Magnitogorsk, Russia.

1. Tarasov V.P. Zagruzochnye ustrojstva shahtnyh pechej [Feeder units of shaft furnaces]. Moscow: Metallurgija, 1974, 312 p.

2. GOST R ISO 10816-1-97. Mashine state control basing on the vibration of non-rotating part measuring. Applied 1998- 07-01. Moscow: Standarts publishing house, 1998. 13 p.

3. Opyt primenenija avtomatizirovannyh stacionarnyh sistem vibrokontrolja i vibrodiagnostiki [Practical experience of automated stationary vibration control and vibration diagnostics system application]. Jelektrotehnicheskie sistemy i kompleksy [Electrotechnical systems and complexes], 2014, vol. 22, pp. 56- 59.